STICHTINGVOLTE.NL ≡ Yläosat Lastenvaatteet Ja Asusteet Biochemistry Cardigans
  • Electrical

  • XFP 1 Loop 32 Zone Addressable Fire Panel (C-TEC CAST protocol) (408255)

XFP 1 Loop 32 Zone Addressable Fire Panel (C-TEC CAST protocol) (408255)

$41.83 $77.39
DescriptionXFP 1 Loop 32 Zone Addressable Fire Panel (C-TEC CAST protocol)Solving the complex challenge of rapid detection and notification, this XFP 1 Loop 32 Zone Addressable Fire Panel (C-TEC CAST protocol) is a vital integration point for any C-TEC fire safety systems.XFP 1 Loop 32 Zone Addressable Fire Panel (C-TEC CAST protocol) C-TEC’s tried and trusted XFP single loop 32 zone addressable fire alarm panel – now available with C-TEC’s own digital fire alarm system protocol, CAST. With a powerful 40V 500mA loop driver allowing the connection of up to 255 CAST devices, the installation of a cost-effective, feature-packed addressable fire alarm system has never been easier. Always thought of the XFP as an entry-level fire panel? Think again. Thanks to CAST’s multiple type codes, high speed data transmission and two speedy soft addressing options (automatic via the panel or manually via a handheld programmer/device tester), it is undoubtedly one of the most powerful single loop fire panels around. This, and its ability to sit on a network of up to 8 XFP master panels, makes it ideal for use in small to medium sized stand-alone applications and larger, more sophisticated installations alike. More Information: PROTOCOL FEATURES: CAST’ is the world’s most-advanced ‘distributed intelligence’ fire alarm system protocol. Conceived, designed and realised by C-TEC as part of a five-year, multi-million pound project, it involved the creation of a powerful proprietary communication protocol (C-TEC Addressable System Technology, CAST) and multiple control panels & field devices. Now available to purchase, its key features include:255 devices per loop.Autonomous decision-making for faster response times.Multiple type codes.40V loop drive voltage.Two ‘soft’ addressing options – automatic via the panel or manual via a powerful handheld programmer.Powerful multi-level addressing facilitates easy device addition and swapped device identification.Multiple functionality at a single address (integrated devices) – due 2019.Volumes, tones & detector modes can be changed at compatible panels.High-speed data transmission and robust data transfer.Intrinsically EN54-13 compliant.Provides geographical location of short and open circuit faults (a short circuit isolator is included as standard in every CAST field device).Replace device function.Programmable multi-function status LED.Future seamless integration with other CAST life safety systems reducing energy, servicing, installation and repair costs.Designed and manufactured in the UK. PANEL FEATURES:Certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependency/coincidence functions.A day/night (building occupied/unoccupied) function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers.An integral EN54-4/A2 switch mode.Adjustable contamination levels.Earth fault monitoring.Combined keypad / keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel. Technical Specification:Approvals/certifications: Certified to EN54-2/4 by the LPCB.Protocol/compatibility: C-TEC CAST.Mains supply: 230V 50/60Hz.Mains rated current: 680mA maximum.Internal power supply: 27Vdc nominal.Total output current limited to: 3A @ 230Vac (Imax.A 250mA; Imin. 70mA).Quiescent current: 80mA (loop unloaded).Max battery size and type: 2 x 12V 7Ah VRLA connected in series.No. of loop drivers: 1.Max. loop output current: 500mA (40V max).Max. loop length: 1KM.Max. addressable devices per loop: 255.No. of conventional sounder circuits: 2 (Max. length per circuit is 500m).EOL resistor value: 6800Ω 5% Tol. 0/25W (blue, grey, red, gold).Max. sounder output current: 400mA.Auxiliary relays: 3 x Programmable Relays (programmable from C&Es). 1 x Fault Relay (active when no faults are present). Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc.Other outputs: 24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current 100mA.Auxiliary inputs: 2 x Programmable Inputs (programmable from C&Es). Connect to 0V to trigger, Max. input voltage 27V (non-latching).PC connection: PC connection via RS232 molex connector (supplied in XFP507 upload/download software kit); No printer connection available.Indicators: 2 line x 40 character backlit display; 32 Zonal LEDs, General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault; System Fault.Connections: Fixed, largest acceptable conductor size 1mm2.Expansion connections: 2-wire RS485 non-redundant network/repeater connection available via optional AFP711 network card. Max. 8 mains per network or 8 repeaters per non-networked main. Limit 1KM (main panel network) or 500M (repeater network).Product dimensions (mm: 410 W x 250 H x 80 D mm (base); 439 W x 274 H x 7 D mm (lid).Hole required for semi-flush mounting: 412 W x 255 H x 50 D mm. Requires XFP385 bezelConstruction & finish: Metal.IP Rating: IP30.Weight: 4.5kg (no batteries).Operating conditions/temperature: -5ºC to 40ºC. Max relative humidity: 95%.Integrated within a wider network of professional fire safety systems, this unit ensures your emergency control hardware operate with maximum efficiency. Technical Insight: Advanced microprocessor control provides intelligent drift compensation, ensuring consistent performance over the lifespan of the device. The XFP 1 Loop 32 Zone Addressable Fire Panel (C-TEC CAST protocol) utilizes C-TEC’s proprietary sensing logic to filter out environmental noise while prioritizing fire signatures.Installation Pro-Tip: Ensure the mains supply is fed from a dedicated, clearly labeled ‘Fire Alarm’ fused spur.Compliance Framework: Fully tested and certified to relevant UK standards for C-TEC professional ecosystems.The Evolution Advantage��️ Verified C-TEC Distribution: Guaranteed authentic hardware with full support.�� Logistics Excellence: Rapid UK-wide dispatch for time-critical safety projects.�� Installer Support: Direct access to technical guidance for complex system commissioning.✅ Quality Assured: All hardware meets current UKCA/CE and BS standards.
Electrical

Electrical

  • XFP 1 Loop 32 Zone Addressable Fire Panel (C-TEC CAST protocol) (408255)
    $41.83 $77.39
  • Honeywell ST9400C 7 Day 2 Channel Programmer
    $72.44 $130.39
  • Heatmiser UH8-RF - 8 Zone Wireless Wiring Centre
    $41.71 $65.07
  • Heatmiser UH8-N - 8 Zone 12v Wiring Centre
    $66.93 $102.4
  • ActiV Multi-Sensor Fire Detector (8408A2)
    $17.09 $28.54
  • Heatmiser UH8 - 8 Zone 230v Underfloor Heating Wiring Centre
    $59.9 $98.24
  • Heat Detector FT64 (TC1)
    $23.44 $28.59
  • XFP 2 Loop 32 Zone Addressable Fire Panel (C-TEC CAST protocol) (F663C0)
    $66.13 $125.65
  • Wireless Thermostat & Receiver - Slimline-RF Kit
    $64.8 $91.37
  • ActiV Rate of Rise Heat Detector (910D93)
    $12.59 $20.78
  • Heatmiser UH4 - 4 Zone 230v Underfloor Heating Wiring Centre
    $59.9 $111.42
  • Heatmiser UH6 - 6 Zone Compact 230v Wiring Centre
    $59.9 $77.88
  • ActiV Optical Smoke Detector (54463F)
    $15.29 $20.03
  • XFP 1 Loop 16 Zone Addressable Fire Panel (C-TEC CAST protocol) (95556B)
    $42.69 $84.95
  • ActiV Non-Diode Base (745773)
    $33.97 $42.46
  • Honeywell T6360B 1028 Room Thermostat
    $14.44 $22.95

© 2026 - STICHTINGVOLTE.NL